China Medical X-reyi collimator oluzenzekelayo x-reyi collimator RF202 umenzi kunye noMboneleli | Sailray
I-X-reyi ye-X-reyi yonyango oluzenzekelayo i-x-reyi collimator RF202

I-X-reyi ye-X-reyi yonyango oluzenzekelayo i-x-reyi collimator RF202

I-X-reyi ye-X-reyi yonyango oluzenzekelayo i-x-reyi collimator RF202

Inkcazelo emfutshane:

Iimbonakalo
Ifanelekile kwi-tube voltage 150kV, i-DR digital kunye nezixhobo eziqhelekileyo zokuxilonga i-X-ray
 Indawo ye-X-reyi yemitha inoxande
Ukuthobela imigangatho efanelekileyo yesizwe neyeshishini
Ukuthembeka okuphezulu kunye nokusebenza kweendleko eziphezulu
 Ukusebenzisa umaleko omnye kunye neeseti ezimbini zamagqabi okukhokela kunye nesakhiwo esikhethekileyo sangaphakathi sokukhusela ukukhusela i-X-rays.
 Ukulungelelaniswa kwentsimi yombane ngumbane, ukuhamba kweqabunga elikhokelayo liqhutywa yi-motor stepping, kunye nentsimi ye-irradiation ngokuqhubekayo
 Lawula umda we-beam ngonxibelelwano lwebhasi ye-CAN okanye inqanaba lokutshintsha, okanye ulawule ngesandla isithinteli se-beam phambi kwakho, kwaye isikrini se-LCD sibonisa ubume kunye neeparamitha zomda womqadi.
Ibala lokukhanya elibonakalayo lamkela iibhalbhu ze-LED ezinokukhanya okuphezulu
Isekethe yokulibaziseka yangaphakathi inokucima ngokuzenzekelayo ibhalbhu emva kwemizuzwana engama-30 yokukhanya, kwaye inokucima ibhalbhu ngesandla ngesandla ngexesha lokukhanya ukwandisa ubomi bebhalbhu kunye nokonga amandla.
Unxibelelwano olufanelekileyo kunye noluthembekileyo lomatshini kunye ne-X-ray ityhubhu, kulula ukuyilungisa


Iinkcukacha zeMveliso

Intlawulo kunye neMiqathango yokuThumela:

Iithegi zeMveliso

Iiparamitha zobugcisa

IVoltage enkulu 150KV
Ubuninzi bendawo yokhuselo lweX-reyi 430mm×430mm (SID=100cm)
Ukukhanya okuphakathi kwendawo yokukhanya > 160 lux
Umda wokuchasana nomlinganiselo >4:1
Imfuno yonikezelo lombane yesibane sokubonisa 24V AC/150W
Ubude bendawo yeX-reyi eqaqambileyo Kanye 30S
Umgama ukusuka kwindawo ekuJoliswe kuyo yetyhubhu ye-X-reyi ukuya kwinqwelomoya ye-collimator SID (mm)(ukhetho) 60
Uhluzo(Indalo) 75kV 1mmAl
Uhluzo(Ongeziweyo) Ukuzikhethela kwangaphandle
Indlela yokulawula Umbane / Incwadana
Qhuba injini Imoto yeStepper
Ulawulo lweeMoto Iimpawu zeNqanaba leTTL
Ukufunyanwa kwesikhundla I-potentiometer
Igalelo lamandla AC24V/DC24V
(SID)Iteyiphu yokulinganisa ngokuzikhethela
Iziko lelaser imiyalelo ngokuzikhethela
Ubungakanani(mm)(W×L×H) 185×230×145
Ubunzima(Kg) 7.2

Iiparamitha eziphambili zobugcisa kunye nezalathi

 X-reyi ukuvuza: <1mGy/h (150kV, 4mA)
 Umgama osuka ekugxininiseni ityhubhu ye-X-ray ukuya kwindawo yokubeka i-beam limiter: 60mm (inokutshintshwa ngokwemibhobho eyahlukeneyo)
Obona mmandla wokukhanya kwemitha: 43cmX43cm (SID=1m)
Ubuncinane bommandla wokukhanya kwemitha: <5cmX5cm (SID=1m)
 Ukukhanya kwebala elibonakalayo: >140lux (SID=1m)
 Ukuhambelana kwebala lokukhanya: <2%@SID
Uhluzo lwendalo: 1mmAl/75kV
Igalelo lamandla entsimi yokukhanya: 24VAC/50W okanye DC24V/1A
 Igalelo lamandla olawulo lombane: 24VDC/2A
Iprothokholi yebhasi yeCAN: CAN2.0A
 Imilinganiselo: 186mm×230mm×145mm (ubude×ububanzi×ubude)
Ubunzima: 7.2kg

Ukhetho:
Icebo elongezelelweyo langaphandle
Ujongano lombane olukhethekileyo
Ujongano olukhethekileyo lwebhola yombhobho

Usetyenziso

Le x-reyi collimator ilungele ityhubhu voltage 150kV, DR digital kunye nezixhobo X-reyi eziqhelekileyo zokuxilonga.


  • Ngaphambili:
  • Okulandelayo:

  • Ubuncinci boMyalelo woMyalelo: 1pc

    Xabiso:Negotiation

    Iinkcukacha zokupakisha: I-100pcs ngebhokisi okanye ilungiselelwe ngokobuninzi

    Ixesha lokuhambisa: Iiveki ze-1 ~ 2 ngokobuninzi

    Imigaqo yentlawulo: 100% T/T kwangaphambili okanye WESTERN UNION

    Ukubonelela ngeAmandla: 1000pcs / ngenyanga

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi