Iimveliso

Iimveliso

  • 100KV High Voltage Cable kwiYunithi yeX-reyi

    100KV High Voltage Cable kwiYunithi yeX-reyi

    Umbane olinganisiweyo: I-100KVDC yonyango Intambo yombane oguquguqukayo ophezulu

    Usetyenziso oluqhelekileyo lulandelayo:

    1,Izixhobo zex-reyi zonyango ezifana ne-x-reyi eqhelekileyo, i-computer tomography kunye ne-angiography

    izixhobo.

    2,I-x-reyi yoshishino neyenzululwazi okanye izixhobo ze-electron beam ezifana ne-electron microscopy

    kunye nezixhobo ze-x-ray diffraction.

    3,Uvavanyo lwamandla asezantsi ombane aphezulu kunye nezixhobo zokulinganisa.

  • X-ray Tube Assembly ilingana E7252X RAD14

    X-ray Tube Assembly ilingana E7252X RAD14

    ◆ X-reyi indibano yetyhubhu yazo zonke iimviwo zokuxilonga kunye neendawo zokusebenzela zeradiographic eziqhelekileyo okanye zedijithali kunye nefluoroscopic.
    ◆Ukufakwa kwetyhubhu ye-anode x-reyi ejikelezayo ngesantya esiphezulu
    ◆ Iimpawu zofakelo: 12° Rhenium-Tungsten molybdenum target (RTM)
    ◆ Iindawo ekugxilwe kuzo: Encinci 0.6, Enkulu: 1.2
    ◆ Ubuninzi bombane ityhubhu: 150kV
    ◆Ihlala ne-IEC60526 uhlobo lwezixhobo zentambo ze-high-voltage
    ◆ Ijeneretha yamandla ombane aphezulu kufuneka ihambelane ne-IEC60601-2-7
    ◆ UHlelo lwe-IEC (IEC 60601-1:2005): ISIXHOBO SEKlasi I ME
  • I-X-RAY TUBE EFANELEKILEYO TOSHIBA E7242

    I-X-RAY TUBE EFANELEKILEYO TOSHIBA E7242

    Isicelo: Indibano yetyhubhu ye-X-ray kuzo zonke iimviwo zesiqhelo zokuxilonga kunye nesiqhelo
    okanye iindawo zokusebenzela zeradiographic kunye nefluoroscopic
    ◆ Iimpawu zofakelo : 12.5° Rhenium-Tungsten molybdenum target (RTM)
    ◆ Iindawo ekugxilwe kuzo: Encinci 0.6, Enkulu: 1.2
    ◆ Ubona buninzi bombane wetyhubhu: 125kV
    ◆Ihlala ne-IEC60526 uhlobo lwezixhobo zentambo ze-high-voltage
    ◆ Ijeneretha yamandla ombane aphezulu kufuneka ihambelane ne-IEC60601-2-7
    ◆ UHlelo lwe-IEC (IEC 60601-1:2005): Udidi lwe-I ME IZIXHOBO
  • X-reyi Exposure Switch Hand Omron C2U HS-01

    X-reyi Exposure Switch Hand Omron C2U HS-01

    Igama leMveliso: X-ray exposure hand switch
    Igama leBrand: SAILRAY
    Isiqinisekiso: CE, ROHS
    Max.Okwangoku: 2A
    Max.Umbane: 30VDC
    Uhlobo: Uhlobo lwangaphakathi lwe-Omron microswitch
    Ubomi boMbane: amaxesha angama-200,000
    Ubomi boomatshini: amaxesha ayi-1,000,000
    Izinto zeShell:Iplastiki yeABC
    Ubude: 3m, 5m
    Cores: 3 core, 4 core
    Ukulungiselela:Iyafumaneka
    Isidibanisi: sinokulungiswa kwi-DB9 isidibanisi okanye i-RJ45, i-RJ11 isidibanisi
  • X-ray Tyhila iqhosha Tshintshela Omron Microswitch Uhlobo HS-02

    X-ray Tyhila iqhosha Tshintshela Omron Microswitch Uhlobo HS-02

    Umzekelo: HS-02
    Uhlobo: Ukunyathela kabini
    Ukwakhiwa kunye nezinto eziphathekayo: Nge-Omron micro switch, i-PU i-coil cover cover kunye neengcingo zobhedu
    Iingcingo kunye nentambo yekhoyili: 3cores okanye 4cores, 3m okanye 5m okanye ubude obulungiselelweyo
    Intambo: 24AWG cable okanye 26 AWG cable
    Ubomi boomatshini: amaxesha ezigidi eziyi-1.0
    Ubomi bombane: amaxesha angama-100 amawaka
    Isiqinisekiso: CE, RoHS

  • X-ray Tyhila iqhosha Tshintshela Omron Microswitch Uhlobo HS-04

    X-ray Tyhila iqhosha Tshintshela Omron Microswitch Uhlobo HS-04

    Umzekelo: HS-04
    Uhlobo: Ukunyathela kabini
    Ukwakhiwa kunye nezinto eziphathekayo: Nge-Omron micro switch, i-PU i-coil cover cover kunye neengcingo zobhedu
    Iingcingo kunye nentambo yekhoyili: 3cores okanye 4 cores, 2.2m okanye 5m
    Ubomi bomatshini: amaxesha ezigidi ezingama-50.0
    Ubomi bombane: amaxesha angama-300 amawaka
    Isiqinisekiso: CE, ROHS
    Isidibanisi: sinokulungiswa kwi-RJ45 isinxibelelanisi, iplagi yomoya, isidibanisi seDB9
  • X-ray Tyhila iqhosha Tshintshela Omron Microswitch Uhlobo HS-04-1

    X-ray Tyhila iqhosha Tshintshela Omron Microswitch Uhlobo HS-04-1

    Umzekelo: HS-04-1
    Uhlobo: Ukunyathela ezimbini ngeqhosha lesibane se-Collimator
    Ukwakhiwa kunye nezinto eziphathekayo: Nge-Omron micro switch, i-PU i-coil cover cover kunye neengcingo zobhedu
    Iingcingo kunye nentambo yekhoyili: 4cores, 2.2m okanye 5m
    Ubomi bomatshini: amaxesha ezigidi ezingama-50.0
    Ubomi bombane: amaxesha angama-300 amawaka
    Isiqinisekiso: CE, CQC, ROHS
    Isidibanisi: singamiselwa RJ45,RJ11 isidibanisi
    Sinokuyilungiselela wena ubude bentambo kunye nocingo lwentambo.

     

  • X-ray Iqhosha lokutyhala Tshintshela Uhlobo lwe-Omron Microswitch 19 HS-01-1

    X-ray Iqhosha lokutyhala Tshintshela Uhlobo lwe-Omron Microswitch 19 HS-01-1

    Umzekelo: HS-01-1
    Uhlobo: Ukunyathela okukodwa
    Ukwakhiwa kunye nezinto eziphathekayo: Nge-Omron micro switch, i-PU i-coil cover cover kunye neengcingo zobhedu.

  • X-ray Iqhosha lokutyhala Tshintshela Uhlobo lwe-Omron Microswitch 20 HS-03-1

    X-ray Iqhosha lokutyhala Tshintshela Uhlobo lwe-Omron Microswitch 20 HS-03-1

    Umzekelo: HS-03-1
    Uhlobo: Ukunyathela okukodwa
    Ukwakhiwa kunye nezinto eziphathekayo: Nge-Omron micro switch, i-PU i-coil cover cover kunye neengcingo zobhedu

  • I-X-reyi ye-X-reyi yonyango oluzenzekelayo lwe-x-reyi collimator RF202

    I-X-reyi ye-X-reyi yonyango oluzenzekelayo lwe-x-reyi collimator RF202

    Iimbonakalo
    Ifanelekile kwi-tube voltage 150kV, i-DR digital kunye nezixhobo eziqhelekileyo zokuxilonga i-X-ray
     Indawo ye-X-reyi yemitha inoxande
    Ukuthobela imigangatho efanelekileyo yesizwe neyeshishini
    Ukuthembeka okuphezulu kunye nokusebenza kweendleko eziphezulu
     Ukusebenzisa umaleko omnye kunye neeseti ezimbini zamagqabi okukhokela kunye nesakhiwo esikhethekileyo sangaphakathi sokukhusela ukukhusela i-X-rays.
     Ukulungelelaniswa kwentsimi ye-irradiation ngumbane, ukuhamba kweqabunga elikhokelayo liqhutywa yi-motor stepping, kunye nentsimi yokukhanya ngokuqhubekayo
     Lawula umda we-beam ngonxibelelwano lwebhasi ye-CAN okanye inqanaba lokutshintsha, okanye ulawule ngesandla isithinteli se-beam phambi kwakho, kwaye isikrini se-LCD sibonisa ubume kunye neeparamitha zomda womqadi.
    Ibala lokukhanya elibonakalayo lamkela iibhalbhu ze-LED ezinokukhanya okuphezulu
    Isekethe yokulibaziseka yangaphakathi inokucima ngokuzenzekelayo ibhalbhu emva kwemizuzwana engama-30 yokukhanya, kwaye inokucima ibhalbhu ngesandla ngesandla ngexesha lokukhanya ukwandisa ubomi bebhalbhu kunye nokonga amandla.
    Unxibelelwano olufanelekileyo kunye noluthembekileyo lomatshini kunye ne-X-ray ityhubhu, kulula ukuyilungisa

  • I-X-reyi yoNyango lwe-X-reyi Collimator oluzenzekelayo lwe-X-reyi Collimator SR305

    I-X-reyi yoNyango lwe-X-reyi Collimator oluzenzekelayo lwe-X-reyi Collimator SR305

    Ifanelekile kwizixhobo eziqhelekileyo zokuxilonga i-X-ray kunye ne-tube voltage ye-150kV
     Indawo ye-X-reyi yemitha inoxande
    Ukuthobela imigangatho efanelekileyo yesizwe neyeshishini
    Ubungakanani obuncinci
    Ukuthembeka okuphezulu kunye nokusebenza kweendleko eziphezulu
     Ukusebenzisa iileya ezintathu kunye neeseti ezimbini zamagqabi okukhokela kunye nesakhiwo esikhethekileyo sangaphakathi sokukhusela ukukhusela ii-X-rays.
    Ulungelelwaniso lwentsimi yokukhutshwa kwemitha yezandla, kwaye intsimi yokukhanya isoloko ihlengahlengiswa.
    Ummandla wokukhanya obonakalayo wamkela iibhalbhu ze-LED eziqaqambe kakhulu
    Isekethe yokulibaziseka yangaphakathi inokucima ngokuzenzekelayo ibhalbhu emva kwemizuzwana engama-30 yokukhanya, kwaye inokucima ibhalbhu ngesandla ngesandla ngexesha lokukhanya ukwandisa ubomi bebhalbhu kunye nokonga amandla.
    Unxibelelwano olufanelekileyo kunye noluthembekileyo lomatshini kunye ne-X-ray ityhubhu, kulula ukuyilungisa

  • IManuwali yeX-reyi yeCollimator yoNyango yeX-reyi yomqadi SR302

    IManuwali yeX-reyi yeCollimator yoNyango yeX-reyi yomqadi SR302

    Ifanelekile kwizixhobo eziqhelekileyo zokuxilonga i-X-ray kunye ne-tube voltage ye-150kV
     Indawo ye-X-reyi yemitha inoxande
    Ukuthobela imigangatho efanelekileyo yesizwe neyeshishini
    Ubungakanani obuncinci
    Ukuthembeka okuphezulu kunye nokusebenza kweendleko eziphezulu
    Ukusebenzisa iileya eziphindwe kabini kunye neeseti ezimbini zamagqabi okukhokela kunye nesakhiwo esikhethekileyo sangaphakathi sokukhusela ukukhusela i-X-rays.
    Ulungelelwaniso lwentsimi yokukhutshwa kwemitha yezandla, kwaye intsimi yokukhanya isoloko ihlengahlengiswa.
    Ummandla wokukhanya obonakalayo wamkela iibhalbhu ze-LED eziqaqambe kakhulu
    Isekethe yokulibaziseka yangaphakathi inokucima ngokuzenzekelayo ibhalbhu emva kwemizuzwana engama-30 yokukhanya, kwaye inokucima ibhalbhu ngesandla ngesandla ngexesha lokukhanya ukwandisa ubomi bebhalbhu kunye nokonga amandla.
    Unxibelelwano olufanelekileyo kunye noluthembekileyo lomatshini kunye ne-X-ray ityhubhu, kulula ukuyilungisa

  • 1234Okulandelayo >>> Iphepha 1 / 4