Le mveliso yenziwe yaza yaphuhliswa ngokuvumelana nale mithetho ilandelayo, izikhokelo kunye nemimiselo yoyilo:
◆ UMyalelo weBhunga 93/42/EEC we-14 Juni 1993 malunga nezixhobo zonyango(Ukumakishwa kweCE).
◆ EN ISO 13485:2016 Isixhobo sezonyango—Iinkqubo zolawulo lomgangatho—Iimfuno zolawulo
iinjongo..
◆ EN ISO 14971: 2012Izixhobo zonyango - Ukusetyenziswa kokulawulwa kwengozi kwizixhobo zonyango (ISO 14971: 2007, Corrected version 2007-10-01)
◆ EN ISO15223-1: 2012Izixhobo zonyango——Iimpawu eziza kusetyenziswa neelebhile zesixhobo zonyango, iilebhile kunye nolwazi oluza kunikezelwa Icandelo 1: Iimfuno ngokubanzi
◆IKhomishini yezoMbane yeHlabathi (i-IEC), le migangatho ilandelayo iqwalaselwa ngokukodwa.
Isalathiso esisemgangathweni | Izihloko |
EN 60601-2-54:2009 | Izixhobo zombane zonyango-Icandelo 2-54: Iimfuno ezizodwa zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo kwezixhobo zeX-ray zeradiography kunye neradioscopy |
IEC60526 | Iplagi yentambo ene-voltage ephezulu kunye noqhagamshelo lwesokhethi yezixhobo zonyango zeX-reyi |
IEC 60522:1999 | Ukumiselwa kokucoca ngokusisigxina kweendibano zetyhubhu ze-X-ray |
IEC 60613-2010 | Umbane, i-thermal kunye neempawu zokulayishwa kweetyhubhu ze-X-ray ze-anode ezijikelezayo zokuxilongwa kwezonyango |
IEC60601-1:2006 | Izixhobo zombane zonyango-Icandelo 1: Iimfuno ngokubanzi zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo |
IEC 60601-1-3:2008 | Izixhobo zombane zonyango-Icandelo 1-3: Iimfuno ngokubanzi zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo |
IEC60601-2-28:2010 | Izixhobo zombane zonyango-Icandelo 2-28: Iimfuno ezizodwa zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo kweendibano zetyhubhu zeX-ray zokuxilongwa kwezonyango. |
IEC 60336-2005 | Izixhobo zombane zonyango-iindibano zetyhubhu zeX-ray zokuxilongwa kwezonyango-Iimpawu zeendawo ezigxininisekileyo |
● Uluhlu luqulunqwe ngolu hlobo lulandelayo:
MWHX7360 | Umbhobho | A | Isokhethi yamandla ombane aphezulu ene-90 degree direction |
MWTX73-0.6/1.2-150H | B | Isokethi yamandla ombane aphezulu ene-270 degree direction |
Ipropati | Inkcazo | Umgangatho | |
Amandla engeniso yesiqhelo ye anode | F 1 | F 2 | IEC 60613 |
20kW(50/60Hz) 30kW(150/180Hz | 50kW(50/60Hz) 74kW(150/180Hz) | ||
Umthamo wokugcina ubushushu be-Anode | 212 kJ (300kHU) | IEC 60613 | |
Ubuninzi bomthamo wokupholisa we-anode | 750W | ||
Umthamo wokugcina ubushushu | 900kJ | ||
Max. ukutshatyalaliswa kobushushu okuqhubekayo ngaphandle kwe-Air-circular | 180W | ||
Izinto ze-AnodeI-Anode yokwambathisa izinto eziphezulu | I-Rhenium-Tungsten-TZM(RTM) I-Rhenium-Tungsten-(RT) | ||
I-engile ekujoliswe kuyo (Ref: i-axis yesalathiso) | 12 ° | IEC 60788 | |
X-reyi indibano yetyhubhu yokucoca ngokwendalo | 1.5 mm Al / 75kV | IEC 60601-1-3 | |
Indawo ekujongwe kuyo ixabiso legama (ama) | F1(ingqwalasela encinci) | F2(ujoliso olukhulu) | IEC 60336 |
0.6 | 1.2 | ||
I-X-ray ityhubhu yombane ngegamaRadiographicI-Fluoroscopic | 150kV 125kV | IEC 60613 | |
Idatha yokufudumeza kwe-cathode Max. yangoku Ubuninzi bombane | ≈ / AC, <20 kHz | ||
F1 | F 2 | ||
5.4A ≈9V | 5.4 A ≈17V | ||
Ukuvuza kwemitha kwi-150 kV / 3mA kumgama we-1m | ≤1.0mGy/h | IEC60601-1-3 | |
Ubuninzi bemitha yemitha |
430 × 430mm kwi-SID 1m | ||
Ubunzima bendibano yetyhubhu ye-X-ray | Malunga. 18kg |
Imida | Imida yoMsebenzi | Imida yezoThutho noGcino |
Ubushushu obugciniwe | Ukusuka kwi-10℃ukuya ku40℃ | Ukususela kwi-20℃to 70℃ |
Ubuntu bezizalwane | ≤75% | ≤93% |
Uxinzelelo lweBarometric | Ukusuka kwi-70kPa ukuya kwi-106kPa | Ukusuka kwi-70kPa ukuya kwi-106kPa |
I-stator yesigaba esi-1
Indawo yovavanyo | C-M | C-A |
Ukuxhathisa komoya | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
Ubukhulu bombane obuvumelekileyo bokusebenza (ukuqhuba) | 230V±10% | |
Cebisa ukusebenza kwamandla ombane (ukusebenza) | 160V±10% | |
I-voltage ye-Braking | 70VDC | |
I-voltage esebenzayo ikwi-exposure | 80Vrms | |
I-voltage esebenzayo kwi-fluoroscopy | 20V-40Vrms | |
Ixesha lokuqalisa (kuxhomekeke kwinkqubo yokuqalisa) | 1.2s |
Isilumkiso sokujongana neX-reyi Generator
1.Ukuqhekeka kweZindlu
Ungaze ufake igalelo kumandla abekiweyo kwindibano yetyhubhu yeX-reyi
Ukuba amandla okufakwayo angaphezulu kokucaciswa kwetyhubhu, abangela ubushushu obungaphezulu kwe-anode, faka i-tube yeglasi yokutyumza kwaye ekugqibeleni kubekho iingxaki ezinzulu ezilandelayo ngenxa yokuvelisa uxinzelelo olugqithisileyo ngokunyuka kwe-oyile ngaphakathi kwendibano yezindlu.
Kwimeko enzima ngolo hlobo ebangela ukugqabhuka kwezindlu ngomthwalo ongaphezulu komthwalo, iswitshi yokhuseleko yobushushu ayinakukhusela ityhubhu yeX-ray nokuba iyasebenza.
*Iindawo zokutywina zezindlu ziyaqhekeka.
*Ukulimala komntu kubandakanya ukutshisa ngenxa yokuphuma kweoli eshushu.
*Ingozi yomlilo ngenxa yethagethi ye-anode evuthayo.
I-X-ray generator kufuneka ibe nomsebenzi wokukhusela olawula amandla okufakwayo ukuba abe ngaphakathi kwenkcazo yetyhubhu.
2.Ukothuka koMbane
Ukuthintela umngcipheko wokothuka kombane, esi sixhobo kufuneka siqhagamshelwe kuphela kubonelelo olunomhlaba okhuselayo.
3.Akukho ukulungiswa kwesi sixhobo kuvunyelwe !!
Isilumkiso sokujongana neX-reyi Generator
1.Ngaphezu komlinganiselo
Indibano yetyhubhu yeX-reyi inokophulwa ngokugalelwa nje ipupu enye ngaphezulu kwereyidi.
Nceda ufunde amaphepha omhla wobugcisa ngononophelo kwaye ulandele imiyalelo.
2.Uhluzo olusisigxina
Tukuhluzwa ngokupheleleyo kunye nomgama phakathi kwe-X-reyi ekugxilwe kuyo kunye nomzimba womntu zilawulwa ngokusemthethweni.
They kufuneka kuthotyelwe ummiselo.
3.Ukhuseleko lokutshintsha kweThermal
X-reyi indibano yetyhubhu inokhuseleko lokutshintsha kwe-thermal ukunqanda amandla egalelo angaphezulu xa indlu yetyhubhu ifikelela kubushushu(80℃)yokutshintsha-vula.
Ukutshintsha akukhuthazwa ukudibanisa i-coil ye-stator kwisekethe yochungechunge.
Nokuba utshintsho luyasebenza, ungaze ucime umbane wenkqubo. Iyunithi yokupholisa kufuneka ivulwe ukuba isetyenziswe kunye nesistim.
4.Ukungasebenzi kakuhle okungalindelekanga
Indibano yetyhubhu ye-X-ray inokuba nobungozi bokungasebenzi ngokungalindelekanga ngenxa yokupheliswa kobomi okanye ukungaphumeleli.Ukuba iingxaki ezinzulu ezibangelwa ngumngcipheko ongentla zilindeleke, uyacelwa ukuba ube nesicwangciso sokukhawulelana nokuphepha imeko enjalo.
5.Usetyenziso Olutsha
Ukuba usebenzisa imveliso kunye nesicelo esitsha esingachazwanga kolu phawu okanye ngohlobo olwahlukileyo lwejenereyitha yeX-reyi, nceda uqhagamshelane nathi ukuze uqinisekise ukufumaneka kwayo.
1 .Ukusasazeka kweX-reyiukhuselo
Le mveliso izalisekisa iimfuno ze-IEC 60601-1-3.
Le ndibano yetyhubhu ye-X-reyi ikhupha imitha ye-X-reyi ekusebenzeni.Kuphela ngokuhambelanayo kuphela ngabasebenzi abaqeqeshiweyo nabaqeqeshiweyo abavumelekileyo ukuba basebenzise indibano yetyhubhu ye-X-ray.
Iziphumo ezifanelekileyo ze-physiologic zinokubangela ingozi kwisigulana, ukuveliswa kwenkqubo kufuneka kuthathe ukhuseleko olufanelekileyo ukunqanda imitha ye-ionization.
2.Dielectric 0il
Indibano yetyhubhu yeX-reyi ine-dielectric 0il equlathe uzinzo lombane ophezulu. Njengoko iyityhefu kwimpilo yabantu,ukuba ibonakaliswe kwindawo engathintelwanga,kufuneka ilahlwe ngokulandelayo kummiselo wendawo.
3 .I-Operation Atmosphere
Indibano yetyhubhu yeX-reyi ayivumelekanga ukuba isetyenziswe kwi-atmosfera yegesi enokutsha okanye edlayo ·
4.Lungisa iTubhu yangoku
Ngokuxhomekeke kwiimeko zokusebenza,iimpawu zomcu zinokutshintshwa.
Olu tshintsho lunokuthi lube sesichengeni esingaphezulu kweqondo lokuvezwa kwimibhobho yeX-reyi.
Ukuthintela indibano yetyhubhu yeX-reyi ukuba yonakale,lungisa i-tube yangoku rhoqo.
Ngaphandle xa ityhubhu ye-X-reyi ine-arcing Ingxaki kwi-alukusetyenziswa ixesha elide,ukulungiswa kombhobho wangoku kuyafuneka.
5.X-ray Tube Housing Ubushushu
Sukuchukumisa umphezulu wezindlu zetyhubhu yeX-ray nje emva kokusebenza ngenxa yobushushu obuphezulu.
Hlala ityhubhu yeX-reyi ukuze upholiswe.
6.Imida yokusebenza
Ngaphambi kokusetyenziswa,Nceda uqinisekise imeko yokusingqongileyo ingaphakathi kwiiIimits zokusebenza.
7.Nakuphi na ukungasebenzi kakuhle
Nceda uqhagamshelane ne-SAILRAY ngokukhawuleza,ukuba kukho ukungasebenzi kakuhle kwendibano yetyhubhu ye-X-ray kubonwa.
8.Ukulahlwa
Indibano yetyhubhu yeX-reyi kunye netyhubhu iqulethe izinto ezifana neoyile kunye nesinyithi esinzima apho ukulahla okusingqongileyo kunye nokufanelekileyo ngokuhambelana nemithetho esemthethweni yesizwe kufuneka kuqinisekiswe. Ukulahlwa njengenkunkuma yasekhaya okanye yemizi-mveliso akuvumelekanga. Umenzi unazo. ulwazi olufunekayo lobuchwephesha kwaye iya kuthatha indibano yetyhubhu yeX-reyi emva ukulahlwa.
Nceda uqhagamshelane nenkonzo yabathengi ngale njongo.
Ukuba (A) INdawo yokuJonga eNcinci
Ukuba(A) Indawo ekuJoliswe kuyo enkulu
Iimpawu zeThermal zezindlu
SRMWHX7360A
INdibano yoHluzo kunye neCandelo lokuwela iZibuko
I-Rotor Connector Wiring
Ubuncinci boMyalelo woMyalelo: 1pc
Xabiso:Negotiation
Iinkcukacha zokupakisha: I-100pcs ngebhokisi okanye ilungiselelwe ngokobuninzi
Ixesha lokuhambisa: Iiveki ze-1 ~ 2 ngokobuninzi
Imigaqo yentlawulo: 100% T/T kwangaphambili okanye WESTERN UNION
Ukubonelela ngeAmandla: 1000pcs / ngenyanga