I-X-R-Ray Tube iNdibano ilingane ne-E7252x rad14

I-X-R-Ray Tube iNdibano ilingane ne-E7252x rad14

I-X-R-Ray Tube iNdibano ilingane ne-E7252x rad14

Inkcazo emfutshane:

◆ x-ray tube yeNdibano ye-X-Ray Tube kuzo zonke iimviwo eziqhelekileyo zokuxilonga kunye ne-radital okanye yedijithali ye-digital kunye ne-fluoroscopic
Ukukhawulezisa okuphezulu kwi-Anode X-R-Ray Tube
◆ IIMPENDULO:
◆ Amabala agxininisiweyo: Incinci 0.6, enkulu: 1.2
I-biltage ephezulu ye-tube: 150KV
◆ Indawo yokuhlala kunye ne-IEC60526 yohlobo lwe-voltage ephezulu ye-voltage
◆ umvelisi we-voltagege ufanele ukuba akhuphe i-IEC060101-7
I-IEC IEC I-IEC I-IEC I-IEC I-IEC I-IEC I-IEC I-IEC I-IEC (IEC 6060161: 2005): Iklasi ndim

Iinkcukacha zemveliso

Intlawulo & Imigaqo yokuhambisa:

Iimpawu zeMveliso

IMITHETHO, IMIQATHANGO NEMIMISELO

Le mveliso yenziwe kwaye yaphuhliswa kwisivumelwano nemithetho elandelayo, imiyalelo kunye neMigaqo yoYilo:
◆ Isikhokelo seBhunga 93/42 / EEC YA-14 kaJuni 1993 malunga nezixhobo zonyango(Ukumakishwa kwe-CE).
I-ESO 13485: 26 Iinkqubo zokuLawulwa kweMigangatho yezoNyango
iinjongo..
I-ESO 14971: Ukusetyenziswa kolawulo lomngcipheko kwizixhobo zezonyango (ISO 14971: 2007, Inguqulelo eQinisekayo ngo-2007- 10-01)
I-En ESO15223-1: Izixhobo zika-2012 - iisimboli zokusetyenziswa kweelebheli zezonyango, iilebheli kunye nolwazi zinikezelwe kwiCandelo 1: IiMfuno Jikelele
IKhomishini yeZizwe zeMigaqo yeZakhiwo (IEC), le migangatho ilandelayo ithathelwa ingqalelo.

Ireferensi esemgangathweni

Ireferensi esemgangathweni

Izihloko

E-60601----5: 2009 Izixhobo zombane zezonyango - Icandelo 2-54: Iimfuno ezithile zenkqubo yokhuseleko kunye nentsebenzo ebalulekileyo yezixhobo ze-X-ray ze-radiography kunye nerediyo
IEC60526 Iplagi ye-volti ye-voltage ephezulu kunye nonxibelelwano lweSocket kwizixhobo ze-X-ray ze-X-ray
IEC 60522: 1999 Ukuzimisela kokuqiniseka okungapheliyo kweendibano ze-X-ray tube
IEC 60613-2010 Iimpawu zombane, i-thermal kunye nokulayisha iimpawu zokujikeleza iityhubhu ze-X-ray ze-ray zokuxilongwa kwezonyango
IEC60601-1: 2006 Izixhobo zombane zezonyango - Icandelo 1: Iimfuno ngokubanzi zoKhuseleko olusisiseko kunye neNtsebenzo ebalulekileyo
IEC 60601-3: 2008 Izixhobo zombane zezonyango-Icandelo 1: Iimfuno ngokubanzi zoKhuseleko olusisiseko kunye neNtsebenzo eyimfuneko - uMgangatho weMigangatho: Ukhuseleko lwe-ray
IEC0000601-28: 2010 Izixhobo zombane zezonyango - Icandelo 2-28: Iimfuneko ezithile zentsebenzo ezisisiseko ze-X-ray tube ze-X-ray tube ze-X-ray tube zezonyango
IEC 60336-2005 Izixhobo zoMbane zoMbane zezoNyango-I-X-Ray Tube i-cube ze-cube zonyango ezixineneyo

Inkcazo

● Uyilo lwenziwe ngolu hlobo lulandelayo:

Mwhx7I-360

Ityhubhu

A

Isokisi yevolthi ephezulu kunye nesidanga se-90

Mwtx73-0.6/1.2-150h

B

Isokisi yevolthi ephezulu kunye nesidanga se-270

Idatha yezobugcisa

Ipropathi

Ukucaciswa

Umgangatho

Amandla okufaka amaNqaku (s) ye-Anode

F 1

F 2

IEC 60613

20kw (50 / 60hz)
I-30kw (i-150 / 180hz
I-50kw (50 / 60hz)
I-74kw (i-150 / 180hz)
 

Umthamo wokuGcinwa kwe-Anode

212 KJ (300KU)

IEC 60613

Ubuninzi bokupholisa amandla e-Anode

I-750w

 
Umthamo wokugcina ubushushu

I-900KJ

 
UMax. Ukuqhubeka kweShando lokuSebenzisa ngaphandle kweSetyhula yomoya

180w

 
Izinto ze-AnodeI-Anode iPhezulu

I-Rhenium-Tungsten-Tzm (RTM)

I-Rhenium-Tungsten- (rt)

 
I-Angle ekujoliswe kuyo (Ref: Ireferensi Axis)

I-12 °

IEC 60788

I-X-R-Ray Tube yeNdibano yeNdibano ye-X-ray tube yendalo

I-1.5 mm i-al / 75KV

IEC 60601-13

Ixabiso lezinto ezihlawulelwayo

F1 (kugxilwe kancinci)

F2 (kugxilwe omkhulu)

IEC 60336

0.6

1.2

 
I-X-ray tube yonyuloI-radiagraphicI-Fluoroscopic

I-150kv

125KV

IEC 60613

Idatha malunga nokufudumeza UMax. okwangoku

I-MAX Voltage

≈ / AC, <20 khz

 

F1

F 2

 

5.4a

≈9V

5.4 A

≈17V

 
Imitha yokuvuza kwi-150 kv / 3MA kumgama we-1m

1.0mgy / h

IEC6060101-3

Ifildi ye-radiation ephezulu

I-430 × 430mm kwi-SID 1M
 
I-X-ray tube yendibano

I-Approx. I-18 kg

 

Iimeko zokusebenza, ukugcinwa kunye nezothutho

Imida

Imida yokusebenza

Ezothutho kunye nokuGcina imida

Ubushushu obugciniwe

Ukusuka kwi-10ukuya kuma-40

Ukusuka- 20to 70

Ubuntu bezizalwane

≤75%

≤93%

Uxinzelelo lwe-barometric

Ukusuka kwi-70kpa ukuya kwi-106Kpa

Ukusuka kwi-70kpa ukuya kwi-106Kpa

 

Ixabiso eliphambili le-stator

I-1-nqanaba lesigaba

Inqaku lovavanyo

C-M

C-A

Ukuxhathisa umoya

≈18.0 ... 22.0ω

≈45.0 ... 55.0ω

I-MAX.PORINGS I-Voltages eSebenzayo (i-run-up)

I-230v ± 10%

Cebisa i-voltage esebenzayo (i-run-up)

I-160v ± 10%

I-Broking Voltage

I-70vdc

Run-kwi-voltage ekuvezeni

I-80vms

Run-kwi-voltage kwi-fluoroscopy

I-20v-40vms

Ixesha lokuhamba (kuxhomekeke kwinkqubo ye-Starter)

1.2s

Isilumkiso

Isilumkiso kwi-interface nge-x-ray generator

1.Nguration Rupture
Ungaze ufake igalelo lamandla okuqhekeka kwi-X-ray tube yendibano
Ukuba amandla okufaka i-tube igqitha ukungqinwa kwe-tube, kubangela ukuba iqondo lokushisa le-ADE, faka i-Tube Glass Shander kwaye ekugqibeleni kwezi ngxaki zibalulekileyo ngenxa yokuveliswa kwe-vaporling yeoyile ngaphakathi kwiNdibano yeOli.
Kwimeko ebaluleke kakhulu ebangela ukuba i-upupture yendlu ngokugqobhoza, ukutshintshwa kwe-shirt ye-shirt engakwazi ukukhusela ityhubhu ye-X-ray nokuba iyasebenza
*Iindawo zokutywina kwezindlu.
*Ukonzakala komntu kubandakanya ukutsha ngenxa yokubaleka i-oyile eshushu.
*Ingozi yomlilo ngenxa ye-flaming anade ithagethi.
Umvelisi we-XAY kufuneka abe nomsebenzi wokhuselo olawula amandla okufaka kwi-tube.

2.Ubothuka
Ukuthintela umngcipheko wokothuka umbane, ezi zixhobo kufuneka zidityaniswe kuphela ekuboneleleni ngoncedo nomhlaba okhusela umhlaba.

 3.Ukulungiswa kwezi zixhobo kuvunyelwe !!

Izilumkiso

Isilumkiso kwi-interface nge-x-ray generator

1.Umgangatho wokulinganisa
Indibano ye-X-ray tube inokwaphuka kunye nokufaka enye idutlulwe ngaphezulu kwe-shot.
Nceda ufunde iimakhishithi zomhla wobugcisa ngononophelo kwaye ulandele imiyalelo.

2.Ukuqina okungapheliyo
TUnqabile ngokupheleleyo kwaye umgama phakathi kwendawo ye-X-ray rage kunye nomzimba womntu ulawulwa ngokusemthethweni.
They kufuneka ithotyelwe kummiselo.

3.Ukhuseleko lwe-shirt ye-shirt
INdibano ye-X-Ray Tube iqhuba i-Inral switch ye-ship yokuthintela amandla okufaka igalelo xa ityhubhu yezindlu ifikelela kubushushu(80)yokutshintsha-vula.
Ukutshintsha akucetyiswa ukudibanisa ukuqhagamshelwa kwe-stator kwisekethe yokuphucula iSeketheri.
Nokuba utshintsho lusebenza, ungaze ujike inkqubo yenkqubo. Icandelo lokupholisa kufuneka lisebenze ukuba lisetyenziswe ngenkqubo.

4.Umsebenzi ongasebenzi kakuhle
Indibano ye-X-ray tube inokuba ngumngcipheko wokuba ungasebenzi ngokungalindelekanga ngenxa yokupheliswa kobomi okanye ukusilela.Ukuba iingxaki ezibi zibangelwa ngumngcipheko ongasentla kulindeleke ukuba ube nesicwangciso sokuxakeka ukuphepha imeko enjalo.

5.Yi isicelo
Ukuba usebenzisa imveliso yesicelo esitsha ukuba ungakhankanywanga kule nkcazo okanye ngohlobo olwahlukileyo lwe-X-generator eyahlukileyo, nceda uqhakamshelane nathi ngokuqinisekisa ukubakho kwawo.

Isilumkiso ngokusebenza

I-1 .x-ray-rayukhuseleko

Le mveliso izalisekisa iimfuno ze-IEC 60601-3.

Le ndibano ye-X-ray rube ikhupha imitha ye-X-ray of Action eSebenzayo

Iziphumo ezifanelekileyo zomzimba zinokubangela ingozi kubaguli, ukuvelisa inkqubo kufuneka zikhuse ngokufanelekileyo ukuphepha imitha ye-ion.

I-Funderitric i-0

Indibano ye-X-ray tube ine-diacritric i-spil iqulethe uzinzo oluphezulu lwe-voltage. Njengoko ityhefu kwimpilo yabantu,Ukuba ityhilwe kwindawo engathintelwanga,Ifanele isuswe ngokulandela ummiselo wasekhaya.

I-3. Imo yolawulo

Indibano ye-X-ray tube ayivunyelwanga ukuba isetyenziswe kwimozulu yomoya evuthayo okanye eyonakalisayo

4.Lungisa ityhubhu yangoku

Kuxhomekeka kwiimeko zokusebenza,Iimpawu zefilim zingaguqulwa.

Olu tshintsho lunokuba yi-IEAD ukuya kwi-Intrenga yokubonisa iNdibano ye-X-Ray Tube.

Ukuthintela indibano ye-X-ray tube isuka kweyonakala,Lungisa ityhubhu yangoku.

Ngaphandle kokuba ityhubhu ye-x-ray inomzungululi kwilUkusetyenziswa kwexesha le-Ong,Uhlengahlengiso lwetyhubhu yangoku iyafuneka.

5.X-ray tube iqondo lobushushu lezindlu

Musa ukuchukumisa kumphezulu we-X- rad Tube yokuhlala emva nje kokusebenza ngenxa yobushushu obuphezulu.

Hlala i-x-ray tube ukuba ipholile.

6.Ukunemida

Ngaphambi kokusetyenziswa,Nceda uqinisekise imeko yokusingqongileyo iphakathi kwe-iiims yokusebenza.

7.Anzi ukungasebenzi kakuhle

I-P1ease fowunelana ne-Samyray kwangoko,Ukuba nakuphi na ukungasebenzi kakuhle kweNdibano ye-X-Ray Tube iqatshelwe.

8.DISCH

Indibano ye-X-ray ye-X-ray kunye netyhubhu inee-oyile ezifana neoyile kunye nezinyithi ezinzima zokuqinisekiswa kwezemigaqo-mvume yendalo kwaye ziyinto echanekileyo.

Nceda uqhagamshelane nenkonzo yabathengi ngenxa yesi sizathu.

Ijika le-ekhuphayo le-cathode

I-MWhx7360 小焦点发射图
I-MWhx7360 大焦点发射图

Ukuba (a) indawo encinci yokugxila

Ukuba (a) indawo egxile kuyo

Ukufudumeza kunye nokupholisa ijika le-anode
I-MWhx7360 yokufudumeza kunye nejika elipholileyo

Ukufudumeza kunye nokupholisa i-curve ye-X-ray tube yendibano

Iimpawu zebhulori yeZindlu

I-MWhhx7360 yezindlu kunye nokupholisa

I-X-R-Ray Tube yeNdibano yeNdibano

I-SRMWHX7360A

I-MWhx7360 外形图

ICWANGCISO LENKCUBEKO NOKUGQIBELA

图片 27

I-Rotor Diring wiring

图片 28

  • Ngaphambili:
  • Okulandelayo:

  • Ubuncinci be-oda ubungakanani: 1pc

    Ixabiso: Uthethathethwano

    Iinkcukacha zokupakisha: I-100PCs ngebhokisi nganye okanye ngokwezifiso ngokwexabiso

    Ukuhanjiswa kwexesha: I-1 ~ 2 iiveki ngokwenani

    Imigaqo yokuhlawula: I-100% T / T kwi-Adst okanye i-Western Union

    Ukubanakho

    Bhala umyalezo apha kwaye uthumele kuthi