I-X-ray tube ilingana neToshiba E7242

I-X-ray tube ilingana neToshiba E7242

I-X-ray tube ilingana neToshiba E7242

Inkcazo emfutshane:

Isicelo: I-X-Ray Tube yeNdibano yazo zonke iimviwo eziqhelekileyo zokuxilonga kunye nesiqhelo
okanye idijithali yediskitha kunye ne-fluoroscopic
Iimpawu: I-12.5 ° ° i-rohenium-tungsblen molybdenum (RTM)
◆ Amabala agxininisiweyo: Incinci 0.6, enkulu: 1.2
Ubuninzi be-tube ye-tube: 125KV
◆ Indawo yokuhlala kunye ne-IEC60526 yohlobo lwe-voltage ephezulu ye-voltage
◆ umvelisi we-voltage uthathe i-IEC606010-2-7
I-IEC IEC I-IEC I-IEC I-IEC I-IEC I-IEC I-IEC I-IEC I-IEC (IEC 6060161: 2005): Iklasi ndim

Iinkcukacha zemveliso

Intlawulo & Imigaqo yokuhambisa:

Iimpawu zeMveliso

Ireferensi esemgangathweni

Ireferensi esemgangathweni

Izihloko

E-60601----5: 2009 Izixhobo zombane zezonyango - Icandelo 2-54: Iimfuno ezithile zenkqubo yokhuseleko kunye nentsebenzo ebalulekileyo yezixhobo ze-X-ray ze-radiography kunye nerediyo
IEC60526 Iplagi ye-volti ye-voltage ephezulu kunye nonxibelelwano lweSocket kwizixhobo ze-X-ray ze-X-ray
IEC 60522: 1999 Ukuzimisela kokuqiniseka okungapheliyo kweendibano ze-X-ray tube
IEC 60613-2010 Iimpawu zombane, i-thermal kunye nokulayisha iimpawu zokujikeleza iityhubhu ze-X-ray ze-ray zokuxilongwa kwezonyango
IEC60601-1: 2006 Izixhobo zombane zezonyango - Icandelo 1: Iimfuno ngokubanzi zoKhuseleko olusisiseko kunye neNtsebenzo ebalulekileyo
IEC 60601-3: 2008 Izixhobo zombane zezonyango-Icandelo 1: Iimfuno ngokubanzi zoKhuseleko olusisiseko kunye neNtsebenzo eyimfuneko - uMgangatho weMigangatho: Ukhuseleko lwe-ray
IEC0000601-28: 2010 Izixhobo zombane zezonyango - Icandelo 2-28: Iimfuneko ezithile zentsebenzo ezisisiseko ze-X-ray tube ze-X-ray tube ze-X-ray tube zezonyango
IEC 60336-2005 Izixhobo zoMbane zoMbane zezoNyango-I-X-Ray Tube i-cube ze-cube zonyango ezixineneyo

Inkcazo

● Uyilo lwenziwe ngolu hlobo lulandelayo:

Mwhx7110A

Ityhubhu

A

Isokisi yevolthi ephezulu kunye nesidanga se-90

Mwtx71-0.6/1.2-125

B

Isokisi yevolthi ephezulu kunye nesidanga se-270

Idatha yezobugcisa

Ipropathi

Ukucaciswa

Umgangatho

Amandla okufaka amaNqaku (s) ye-Anode

F 1

F 2

IEC 60613

20kw (50 / 60hz)

I-40kw (50 / 60hz)

 

Umthamo wokuGcinwa kwe-Anode

I-110 KJ (i-150Khu)

IEC 60613

Ubuninzi bokupholisa amandla e-Anode

500w

 
Umthamo wokugcina ubushushu

I-900KJ

 
UMax. Ukuqhubeka kweShando lokuSebenzisa ngaphandle kweSetyhula yomoya

180w

 
Izinto ze-AnodeI-Anode iPhezulu

I-Rhenium-Tungsten-Tzm (RTM)

I-Rhenium-Tungsten- (rt)

 
I-Angle ekujoliswe kuyo (Ref: Ireferensi Axis)

12.5 °

IEC 60788

I-X-R-Ray Tube yeNdibano yeNdibano ye-X-ray tube yendalo

I-1.5 mm i-al / 75KV

IEC 60601-13

Ixabiso lezinto ezihlawulelwayo

F1 (kugxilwe kancinci)

F2 (kugxilwe omkhulu)

IEC 60336

0.6

1.2

 
I-X-ray tube yonyuloI-radiagraphicI-Fluoroscopic

125KV

I-100KV

IEC 60613

Idatha malunga nokufudumeza UMax. okwangoku

I-MAX Voltage

≈ / AC, <20 khz

 

F1

F 2

 

5.1a

≈7~9V

5.1 A

≈12~I-14 v

 
Imitha yokuvuza kwi-150 kv / 3MA kumgama we-1m

0.5mgy / h

IEC6060101-3

Ifildi ye-radiation ephezulu

I-443 × 44mm kwi-SID 1M

 
I-X-ray tube yendibano

I-Approx. I-18 kg

 

Iimeko zokusebenza, ukugcinwa kunye nezothutho

Imida

Imida yokusebenza

Ezothutho kunye nokuGcina imida

Ubushushu obugciniwe

Ukusuka kwi-10ukuya kuma-40

Ukusuka- 20to 70

Ubuntu bezizalwane

≤75%

≤93%

Uxinzelelo lwe-barometric

Ukusuka kwi-70kpa ukuya kwi-106Kpa

Ukusuka kwi-70kpa ukuya kwi-106Kpa

 

Ixabiso eliphambili le-stator

I-1-nqanaba lesigaba

Inqaku lovavanyo

C-M

C-A

Ukuxhathisa umoya

≈18.0 ... 22.0ω

≈45.0 ... 55.0ω

I-MAX.PORINGS I-Voltages eSebenzayo (i-run-up)

I-230v ± 10%

Cebisa i-voltage esebenzayo (i-run-up)

I-160v ± 10%

I-Broking Voltage

I-70vdc

Run-kwi-voltage ekuvezeni

I-80vms

Run-kwi-voltage kwi-fluoroscopy

I-20v-40vms

Ixesha lokuhamba (kuxhomekeke kwinkqubo ye-Starter)

1.2s

Isilumkiso ngokusebenza

I-1 .x-ray-rayukhuseleko

Le mveliso izalisekisa iimfuno ze-IEC 60601-3.

Le ndibano ye-X-ray rube ikhupha imitha ye-X-ray of Action eSebenzayo

Iziphumo ezifanelekileyo zomzimba zinokubangela ingozi kubaguli, ukuvelisa inkqubo kufuneka zikhuse ngokufanelekileyo ukuphepha imitha ye-ion.

I-Funderitric i-0

Indibano ye-X-ray tube ine-diacritric i-spil iqulethe uzinzo oluphezulu lwe-voltage. Njengoko ityhefu kwimpilo yabantu,Ukuba ityhilwe kwindawo engathintelwanga,Ifanele isuswe ngokulandela ummiselo wasekhaya.

I-3. Imo yolawulo

Indibano ye-X-ray tube ayivunyelwanga ukuba isetyenziswe kwimozulu yomoya evuthayo okanye eyonakalisayo

4.Lungisa ityhubhu yangoku

Kuxhomekeka kwiimeko zokusebenza,Iimpawu zefilim zingaguqulwa.

Olu tshintsho lunokuba yi-IEAD ukuya kwi-Intrenga yokubonisa iNdibano ye-X-Ray Tube.

Ukuthintela indibano ye-X-ray tube isuka kweyonakala,Lungisa ityhubhu yangoku.

Ngaphandle kokuba ityhubhu ye-x-ray inomzungululi kwilUkusetyenziswa kwexesha le-Ong,Uhlengahlengiso lwetyhubhu yangoku iyafuneka.

5.X-ray tube iqondo lobushushu lezindlu

Musa ukuchukumisa kumphezulu we-X- rad Tube yokuhlala emva nje kokusebenza ngenxa yobushushu obuphezulu.

Hlala i-x-ray tube ukuba ipholile.

6.Ukunemida

Ngaphambi kokusetyenziswa,Nceda uqinisekise imeko yokusingqongileyo iphakathi kwe-iiims yokusebenza.

7.Anzi ukungasebenzi kakuhle

I-P1ease fowunelana ne-Samyray kwangoko,Ukuba nakuphi na ukungasebenzi kakuhle kweNdibano ye-X-Ray Tube iqatshelwe.

8.DISCH

Indibano ye-X-ray ye-X-ray kunye netyhubhu inee-oyile ezifana neoyile kunye nezinyithi ezinzima zokuqinisekiswa kwezemigaqo-mvume yendalo kwaye ziyinto echanekileyo.

Nceda uqhagamshelane nenkonzo yabathengi ngenxa yesi sizathu.

Ijika le-ekhuphayo le-cathode

图片

Ukuba (a) indawo encinci yokugxila

图片 1.2 焦点

Ukuba (a) indawo egxile kuyo

Ukutshata nochungezo

Iimeko: I-Tube Voltiage isigaba sesithathu

I-Station Rip Frequency 50hz/ 60hz

Ndim i)

图片 4

t (s)

Ndim i)

图片 3

t (s)

Ukufudumeza kunye nokupholisa ijika le-anode

  IEC60613

图片 5

Ukufudumeza kunye nokupholisa i-curve ye-X-ray tube yendibano

Iimpawu zebhulori yeZindlu

图片 6

I-X-R-Ray Tube yeNdibano yeNdibano

I-SRMWHXX7110A

图片 7

ICWANGCISO LENKCUBEKO NOKUGQIBELA

图片 27

I-Rotor Diring wiring

图片 28

  • Ngaphambili:
  • Okulandelayo:

  • Ubuncinci be-oda ubungakanani: 1pc

    Ixabiso: Uthethathethwano

    Iinkcukacha zokupakisha: I-100PCs ngebhokisi nganye okanye ngokwezifiso ngokwexabiso

    Ukuhanjiswa kwexesha: I-1 ~ 2 iiveki ngokwenani

    Imigaqo yokuhlawula: I-100% T / T kwi-Adst okanye i-Western Union

    Ukubanakho

    Bhala umyalezo apha kwaye uthumele kuthi