
| Isalathiso esisemgangathweni | Izihloko |
| EN 60601-2-54:2009 | Izixhobo zombane zonyango-Icandelo 2-54: Iimfuno ezizodwa zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo kwezixhobo zeX-ray zeradiography kunye neradioscopy |
| IEC60526 | Iplagi yentambo ene-voltage ephezulu kunye noqhagamshelo lwesokhethi yezixhobo zonyango zeX-reyi |
| IEC 60522:1999 | Ukumiselwa kokucoca ngokusisigxina kweendibano zetyhubhu ze-X-ray |
| IEC 60613-2010 | Umbane, i-thermal kunye neempawu zokulayishwa kweetyhubhu ze-X-ray ze-anode ezijikelezayo zokuxilongwa kwezonyango |
| IEC60601-1:2006 | Izixhobo zombane zonyango-Icandelo 1: Iimfuno ngokubanzi zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo |
| IEC 60601-1-3:2008 | Izixhobo zombane zonyango-Icandelo 1-3: Iimfuno ngokubanzi zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo |
| IEC60601-2-28:2010 | Izixhobo zombane zonyango-Icandelo 2-28: Iimfuno ezizodwa zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo kweendibano zetyhubhu zeX-ray zokuxilongwa kwezonyango. |
| IEC 60336-2005 | Izixhobo zombane zonyango-iindibano zetyhubhu zeX-reyi zokuxilongwa kwezonyango-Iimpawu zeendawo ezigxilwe kuzo |
● Uluhlu luqulunqwe ngolu hlobo lulandelayo:
| MWHX7110A | Umbhobho | A | Isokethi yamandla ombane aphezulu ene-90 degree direction |
| MWTX71-0.6/1.2-125 | B | Isokethi yamandla ombane aphezulu ene-270 degree direction |
| Ipropati | Inkcazo | Umgangatho | |
| Amandla engeniso yesiqhelo ye anode | F 1 | F 2 | IEC 60613 |
| 20kW(50/60Hz) | 40kW(50/60Hz) | ||
| Umthamo wokugcina ubushushu be-Anode | 110 kJ ( 150kHU) | IEC 60613 | |
| Ubuninzi bomthamo wokupholisa we-anode | 500W | ||
| Umthamo wokugcina ubushushu | 900kJ | ||
| Max. ukutshatyalaliswa kobushushu okuqhubekayo ngaphandle kwe-Air-circular | 180W | ||
| Izinto ze-AnodeI-Anode yokwambathisa izinto eziphezulu | I-Rhenium-Tungsten-TZM(RTM) I-Rhenium-Tungsten-(RT) | ||
| I-engile ekujoliswe kuyo (Ref: i-reference axis) | 12.5 ° | IEC 60788 | |
| X-reyi indibano ityhubhu ukuhluzwa ngokwendalo | 1.5 mm Al / 75kV | IEC 60601-1-3 | |
| Indawo ekujongwe kuyo ixabiso legama (ama) | F1(ingqwalasela encinci) | F2(ujoliso olukhulu) | IEC 60336 |
| 0.6 | 1.2 | ||
| I-X-ray ityhubhu yombane ngegamaRadiographicI-Fluoroscopic | 125kV 100kV | IEC 60613 | |
| Idatha yokufudumeza kwe-cathode Max. yangoku Ubuninzi bombane | ≈ / AC, <20 kHz | ||
| F1 | F 2 | ||
| 5.1A ≈7~9V | 5.1 A ≈12~14 V | ||
| Ukuvuza kwemitha kwi-150 kV / 3mA kumgama we-1m | ≤0.5mGy/h | IEC60601-1-3 | |
| Ubuninzi bemitha yemitha | 443 × 443mm kwi-SID 1m | ||
| Ubunzima bendibano yetyhubhu ye-X-ray | Malunga. 18kg | ||
| Imida | Imida yoMsebenzi | Imida yezoThutho noGcino |
| Ubushushu obugciniwe | Ukusuka kwi-10℃ukuya ku40℃ | Ukususela kwi-20℃to 70℃ |
| Ubuntu bezizalwane | ≤75% | ≤93% |
| Uxinzelelo lweBarometric | Ukusuka kwi-70kPa ukuya kwi-106kPa | Ukusuka kwi-70kPa ukuya kwi-106kPa |
I-stator yesigaba esi-1
| Indawo yovavanyo | C-M | C-A |
| Ukuxhathisa komoya | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
| Umthamo wombane ovumelekileyo wokusebenza (ukuqhuba) | 230V±10% | |
| Cebisa ukusebenza kwamandla ombane (ukusebenza) | 160V±10% | |
| I-voltage ye-Braking | 70VDC | |
| I-voltage esebenzayo ekutyhilekeni | 80Vrms | |
| I-voltage esebenzayo kwi-fluoroscopy | 20V-40Vrms | |
| Ixesha lokuqalisa (kuxhomekeke kwinkqubo yokuqalisa) | 1.2s | |
1 .Ukusasazeka kweX-reyiukhuselo
Le mveliso izalisekisa iimfuno ze-IEC 60601-1-3.
Le ndibano yetyhubhu ye-X-reyi ikhupha imitha ye-X-reyi ekusebenzeni.Kuphela ngokuhambelanayo kuphela ngabasebenzi abaqeqeshiweyo nabaqeqeshiweyo abavumelekileyo ukuba basebenzise indibano yetyhubhu ye-X-ray.
Iziphumo ezifanelekileyo ze-physiologic zinokubangela ingozi kwisigulana, ukuveliswa kwenkqubo kufuneka kuthathe ukhuseleko olufanelekileyo ukunqanda imitha ye-ionization.
2.Dielectric 0il
Indibano yetyhubhu yeX-reyi ine-dielectric 0il equlathe uzinzo lwamandla ombane aphezulu. Njengoko iyityhefu kwimpilo yabantu,ukuba ibonakaliswe kwindawo engathintelwanga,kufuneka ilahlwe ngokulandelayo kummiselo wendawo.
3 .I-Operation Atmosphere
Indibano yetyhubhu yeX-reyi ayivumelekanga ukuba isetyenziswe kwi-atmosfera yegesi enokutsha okanye edlayo ·
4.Lungisa iTubhu yangoku
Ngokuxhomekeke kwiimeko zokusebenza,iimpawu zomcu zinokutshintshwa.
Olu tshintsho lunokuthi lube sesichengeni esingaphezulu kweqondo lokuvezwa kwimibhobho yeX-reyi.
Ukuthintela indibano yetyhubhu yeX-reyi ukuba yonakale,lungisa i-tube yangoku rhoqo.
Ngaphandle xa ityhubhu ye-X-reyi ine-arcing Ingxaki kwi-alukusetyenziswa ixesha elide,ukulungiswa kombhobho wangoku kuyafuneka.
5.X-ray Tube Housing Ubushushu
Sukuchukumisa umphezulu wezindlu zetyhubhu yeX-ray nje emva kokusebenza ngenxa yobushushu obuphezulu.
Hlala ityhubhu yeX-reyi ukuze upholiswe.
6.Imida yokusebenza
Ngaphambi kokusetyenziswa,Nceda uqinisekise imeko yokusingqongileyo ingaphakathi kwiiIimits zokusebenza.
7.Nakuphi na ukungasebenzi kakuhle
Nceda uqhagamshelane ne-SAILRAY ngokukhawuleza,ukuba kukho ukungasebenzi kakuhle kwendibano yetyhubhu ye-X-ray kubonwa.
8.Ukulahlwa
Indibano yetyhubhu ye-X-reyi kunye netyhubhu iqulethe izinto ezifana ne-oyile kunye nesinyithi esinzima apho ukuchithwa kokusingqongileyo kunye nokulahla ngokufanelekileyo ngokuhambelana nemimiselo esemthethweni yelizwe jikelele kufuneka kuqinisekiswe.Ukulahlwa njengenkunkuma yasekhaya okanye yezoshishino akuvumelekanga.Umvelisi unolwazi olufunekayo lobugcisa kwaye uya kuthatha indibano ye-X-reyi yetyhubhu ayibuyisele ukuyilahla.
Nceda uqhagamshelane nenkonzo yabathengi ngale njongo.
Ukuba (A) INdawo yokuJonga eNcinci
Ukuba (A) Indawo enkulu ekugxilwe kuyo
Iimeko:ISigaba seSithathu seTube Voltage
I-Stator Power Frequency 50Hz/60Hz
Ndim i)
T(s)
Ndim i)
T(s)
IEC60613
Iimpawu zeThermal zezindlu
SRMWHX7110A
INdibano yoHluzo kunye neCandelo lokuwela iZibuko
I-Rotor Connector Wiring
Ubuncinci boMyalelo woMyalelo: 1pc
Xabiso:Negotiation
Iinkcukacha zokupakisha: I-100pcs ngebhokisi okanye ilungiselelwe ngokobuninzi
Ixesha lokuhanjiswa: Iiveki ze-1 ~ 2 ngokobuninzi
Imigaqo yentlawulo: 100% T/T kwangaphambili okanye WESTERN UNION
Ukubonelela ngeAmandla: 1000pcs / ngenyanga