Ityhubhu ye-X-ray ilingana ne-TOSHIBA E7242

Ityhubhu ye-X-ray ilingana ne-TOSHIBA E7242

Ityhubhu ye-X-ray ilingana ne-TOSHIBA E7242

Inkcazo emfutshane:

Isicelo: Indibano yetyhubhu ye-X-ray kuzo zonke iimviwo zesiqhelo zokuxilonga kunye nesiqhelo
okanye iindawo zokusebenza zedijithali ze-radiographic kunye ne-fluoroscopic
◆Iimpawu ze-insert: 12.5° Rhenium-Tungsten molybdenum target (RTM)
◆Iindawo ezijolisiweyo: Encinci 0.6, Enkulu: 1.2
◆Umbane omkhulu wetyhubhu: 125kV
◆Inokusetyenziselwa ii-receptacles zekhebula ezine-voltage ephezulu ze-IEC60526
◆Ijenereyitha yombane ophezulu kufuneka ihambelane ne-IEC60601-2-7
◆Udidi lwe-IEC (IEC 60601-1:2005):IZIXHOBO ZE-CLOSE I ME

Iinkcukacha zeMveliso

Imigaqo yokuhlawula kunye nokuthumela:

Iithegi zeMveliso

Isalathiso Esiqhelekileyo

Isalathiso Esiqhelekileyo

Izihloko

EN 60601-2-54:2009 Izixhobo zombane zonyango - Icandelo 2-54: Iimfuno ezithile zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo kwezixhobo ze-X-ray ze-radiography kunye ne-radioscopy
IEC60526 Iintambo ze-plug kunye neesokhethi ezidityaniswe nge-high-voltage kwizixhobo ze-X-ray zonyango
I-IEC 60522:1999 Ukumiselwa kokuhluzwa okusisigxina kweendibano zeetyhubhu ze-X-ray
I-IEC 60613-2010 Iimpawu zombane, ubushushu kunye nomthwalo weetyhubhu ze-X-ray ze-anode ezijikelezayo zokuxilongwa kwezonyango
IEC60601-1: 2006 Izixhobo zombane zonyango - Icandelo 1: Iimfuno ngokubanzi zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo
I-IEC 60601-1-3:2008 Izixhobo zombane zonyango - Icandelo 1-3: Iimfuno ngokubanzi zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo - Umgangatho weBali: Ukhuseleko lwemitha kwizixhobo ze-X-ray zokuxilonga
IEC60601-2-28:2010 Izixhobo zombane zonyango - Icandelo 2-28: Iimfuno ezithile zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo kweendibano zeetyhubhu ze-X-ray zokuxilongwa kwezonyango
I-IEC 60336-2005 Izixhobo zombane zonyango-iindibano zeetyhubhu ze-X-ray zokuxilongwa kwezonyango-Iimpawu zeendawo ezijolise kuzo

Inkcazo

●Igama lenziwe ngolu hlobo lulandelayo:

MWHX7110A

Ityhubhu

A

Isokhethi yevolthi ephezulu enecala le-90 degrees

MWTX71-0.6/1.2-125

B

Isokhethi yevolthi ephezulu enecala le-270 degrees

Idatha yoBugcisa

Ipropati

Inkcazo

Umgangatho

Amandla okufaka amagama e-anode

F 1

F 2

I-IEC 60613

20kW(50/60Hz)

40kW(50/60Hz)

 

Umthamo wokugcina ubushushu be-anode

110 kJ (150kHU)

I-IEC 60613

Ubungakanani obukhulu bokupholisa be-anode

500W

 
Umthamo wokugcina ubushushu

900kJ

 
Ukusasazwa kobushushu okuqhubekekayo okuphezulu ngaphandle komoya ojikelezayo

180W

 
Izinto ze-anodeIzinto zokugquma eziphezulu ze-Anode

I-Rhenium-Tungsten-TZM(RTM)

I-Rhenium-Tungsten-(RT)

 
I-engile ekujoliswe kuyo (Ref: i-axis yokubhekisa)

12.5 °

I-IEC 60788

Indibano yetyhubhu ye-X-ray yokuhluza okuqhelekileyo

1.5 mm Al / 75kV

I-IEC 60601-1-3

Ixabiso eliqhelekileyo lendawo yokugxila

F1 (ugxininiso oluncinci)

F2 (ugxininiso olukhulu)

I-IEC 60336

0.6

1.2

 
Ityhubhu ye-X-ray yombane oqhelekileyoI-RadiographicI-Fluoroscopic

125kV

100kV

I-IEC 60613

Idatha yokufudumeza i-cathode Ubuninzi bangoku

Umbane ophezulu

≈ /AC, < 20 kHz

 

F1

F 2

 

5.1A

≈79V

5.1 A

≈1214 V

 
Imitha yokuvuza kwi-150 kV / 3mA kumgama we-1m

0.5mGy/h

IEC60601-1-3

Intsimi enkulu yemitha

443×443mm kwi-SID 1m

 
ubunzima bendibano yetyhubhu ye-X-ray

Malunga ne-18 kg

 

Iimeko zokusebenza, zokugcina kunye nokuthuthwa

Imida

Imida Yokusebenza

Imida yoThutho kunye noGcino

Ubushushu obugciniwe

Ukususela kwi-10ukuya kuma-40

Ukususela kwi- 20to 70

Ubuntu bezizalwane

≤75%

≤93%

Uxinzelelo lweBarometric

Ukusuka kwi-70kPa ukuya kwi-106kPa

Ukusuka kwi-70kPa ukuya kwi-106kPa

 

Amaxabiso angundoqo eStator

I-stator yesigaba esi-1

Indawo yovavanyo

C-M

C-A

Ukumelana nokujika

≈18.0…22.0Ω

≈45.0…55.0Ω

Umbane osebenzayo ophezulu ovumelekileyo (ukuqalisa)

230V±10%

Cebisa i-voltage yokusebenza (ukuqalisa)

160V±10%

I-voltage yokubhuleka

70VDC

I-voltage esebenzayo xa ivezwa

IiVrms ezingama-80

I-voltage esebenzayo kwi-fluoroscopy

20V-40Vrms

Ixesha lokusebenza (kuxhomekeke kwinkqubo yokuqalisa)

1.2s

Isilumkiso Ekusebenzeni

1. Imitha ye-X-reyiukhuseleko

Le mveliso ihlangabezana neemfuno ze-IEC 60601-1-3.

Olu lungiselelo lwetyhubhu ye-X-ray lukhupha imitha ye-X-ray xa lusebenza. Kuphela ngabasebenzi abafanelekileyo nabaqeqeshwe ngokufanelekileyo abavumelekileyo ukusebenzisa olu lungiselelo lwetyhubhu ye-X-ray.

Iziphumo ezifanelekileyo zomzimba zinokubangela ingozi kwisigulana, abavelisi benkqubo kufuneka bakhuseleke ngokufanelekileyo ukuze baphephe imitha ye-ionization.

2. I-Dielectric 0il

I-X-ray tube assembly ine-dielectric 0il equlethwe yi-0il ukuze i-voltage ibe nozinzo oluphezulu. Njengoko iyingozi kwimpilo yabantuukuba ivezwe kwindawo engathintelwangakufuneka ilahlwe ngokwemigaqo yendawo.

3. Imozulu yokusebenza

Ukuhlanganiswa kwetyhubhu ye-X-ray akuvumelekanga ukuba kusetyenziswe kwimozulu yegesi evuthayo okanye ebolileyo ·

4Lungisa iTube Current

Kuxhomekeke kwiimeko zokusebenzaiimpawu zefilament zisenokutshintsha.

Olu tshintsho lunokubangela ukuba i-X-ray tube assembly ibe yingozi kakhulu.

Ukuthintela ukuba indibano yetyhubhu ye-X-ray ingonakalilungisa umsinga wetyhubhu rhoqo.

Ngaphandle koko xa ityhubhu ye-X-ray ine-arcing Ingxaki kwi-alukusetyenziswa kwexesha elideUkulungiswa komsinga wetyhubhu kuyadingeka.

5Ubushushu beZindlu zeThubhu yeX-ray

Musa ukuyichukumisa indawo ehlala ityhubhu ye-X-ray emva nje kokuhlinzwa ngenxa yobushushu obuphezulu.

Ityhubhu ye-X-ray mayihlale ipholile.

6Imida yokusebenza

Ngaphambi kokusetyenziswaNceda uqinisekise ukuba imeko yokusingqongileyo ikwii-Iimits ezisebenzayo.

7.Nasiphi na isiphene

P1ehlisa unxibelelwano kwi-SAILRAY ngoko nangokoukuba kukho ukungasebenzi kakuhle kwendibano yetyhubhu ye-X-ray eqatshelweyo.

8. Ukulahla

I-X-ray tube assembly kunye ne-tube ziqulethe izinto ezifana neoyile kunye neentsimbi ezinzima apho kufuneka kuqinisekiswe ukuba ziyalahlwa ngendlela enobuhlobo nokusingqongileyo kwaye zilahlwe ngokufanelekileyo ngokuhambelana nemigaqo esemthethweni yesizwe. Ukulahlwa kwenkunkuma yasekhaya okanye yemizi-mveliso akuvumelekanga. Umenzi unolwazi lobuchwephesha olufunekayo kwaye uza kuyibuyisela i-X-ray tube assembly ukuze ilahlwe.

Nceda unxibelelane nenkonzo yabathengi ngale njongo.

Iigophe zokukhupha i-cathode

图片

Ukuba(A) Indawo encinci yokugxila

Imifanekiso ye-1.2

Ukuba(A) Indawo Enkulu Yokugxila

Ukulayisha okukodwa kunye nochungechunge

Iimeko: I-Tube Voltage yeSigaba sesithathu

Ubuninzi bamandla eStator 50Hz/60Hz

Ndim i)

umfanekiso we-4

t(s)

Ndim i)

Imifanekiso ye3

t(s)

Ijika lokufudumeza nokupholisa le-anode

  IEC60613

图片5

Ukufudumeza kunye nokupholisa ijika lendibano yetyhubhu ye-X-ray

Iimpawu zobushushu bezindlu

图片6

Imizobo yobukhulu bendibano yetyhubhu ye-X-ray

SRMWHX7110A

Umfanekiso we7

Indibano yesihluzo kunye neCandelo eliMnqamlezo lePort

Umfanekiso we27

Iintambo zoQhagamshelo lweRotor

Umfanekiso we28

  • Ngaphambili:
  • Okulandelayo:

  • Ubungakanani obuncinci be-oda: 1pc

    Ixabiso: Ingxoxo

    Iinkcukacha zokuPakisha: 100pcs ngebhokisi nganye okanye eyenziwe ngokwezifiso ngokwenani

    Ixesha lokuHanjiswa: Iiveki ezi-1 ~ 2 ngokobungakanani

    Imigaqo yokuhlawula: 100% T/T kwangaphambili okanye i-WESTERN UNION

    Amandla okubonelela: 1000pcs/ngenyanga

    Bhala umyalezo wakho apha uze uwuthumele kuthi