INdibano yeZindlu ye-X-ray ye-X-ray TOSHIBA E7239X uMvelisi kunye noMboneleli |Sailray
X-ray Tube Housing Assembly TOSHIBA E7239X

X-ray Tube Housing Assembly TOSHIBA E7239X

X-ray Tube Housing Assembly TOSHIBA E7239X

Inkcazelo emfutshane:

◆ X-reyi indibano yetyhubhu yazo zonke iimviwo zokuxilonga kunye neendawo zokusebenzela zeradiographic eziqhelekileyo okanye zedijithali kunye nefluoroscopic.

◆ Iimpawu zokufaka : 16° ​​Rhenium-Tungsten molybdenum target (RTM)

◆ Iindawo ekugxilwe kuzo: Encinci 1.0, Enkulu: 2.0

◆ Owona mbane wetyhubhu omkhulu:125kV

◆Ihlala ne-IEC60526 uhlobo lwezixhobo zentambo ze-high-voltage

◆ Ijenereyitha yombane ophezulu kufuneka ihambelane ne-IEC60601-2-7

UHlelo lwe-IEC (IEC 60601-1: 2005): Udidi lwe-I ME IZIXHOBO


Iinkcukacha zeMveliso

Intlawulo kunye neMiqathango yokuThumela:

Iithegi zeMveliso

Imithetho, imigangatho kunye nemimiselo

Le mveliso yenziwe yaza yaphuhliswa ngokuvumelana nale mithetho ilandelayo, izikhokelo kunye nemimiselo yoyilo:
◆ UMyalelo weBhunga 93/42/EEC we-14 Juni 1993 malunga nezixhobo zonyango(Ukumakishwa kweCE.
◆ EN ISO 13485:2016 Isixhobo sezonyango—Iinkqubo zolawulo lomgangatho—Iimfuno zolawulo
iinjongo..
◆ EN ISO 14971: 2012Izixhobo zonyango - Ukusetyenziswa kokulawulwa kwengozi kwizixhobo zonyango (ISO 14971: 2007, Corrected version 2007-10-01)
◆ EN ISO15223-1: 2012Izixhobo zonyango——Iimpawu eziza kusetyenziswa neelebhile zesixhobo zonyango, iilebhile kunye nolwazi oluza kunikezelwa Icandelo 1: Iimfuno ngokubanzi
IKhomishini yezoMbane yeHlabathi (i-IEC), le migangatho ilandelayo iqwalaselwa ngokukodwa.

Isalathiso esisemgangathweni

Isalathiso esisemgangathweni

Izihloko

EN 60601-2-54:2009 Izixhobo zombane zonyango-Icandelo 2-54: Iimfuno ezizodwa zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo kwezixhobo zeX-ray zeradiography kunye neradioscopy
IEC60526 Iplagi yentambo ene-voltage ephezulu kunye noqhagamshelo lwesokhethi yezixhobo zonyango zeX-reyi
IEC 60522:1999 Ukumiselwa kokucoca ngokusisigxina kweendibano zetyhubhu ze-X-ray
IEC 60613-2010 Umbane, i-thermal kunye neempawu zokulayishwa kweetyhubhu ze-X-ray ze-anode ezijikelezayo zokuxilongwa kwezonyango
IEC60601-1:2006 Izixhobo zombane zonyango-Icandelo 1: Iimfuno ngokubanzi zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo
IEC 60601-1-3:2008 Izixhobo zombane zonyango-Icandelo 1-3: Iimfuno ngokubanzi zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo
IEC60601-2-28:2010 Izixhobo zombane zonyango-Icandelo 2-28: Iimfuno ezizodwa zokhuseleko olusisiseko kunye nokusebenza okubalulekileyo kweendibano zetyhubhu zeX-ray zokuxilongwa kwezonyango.
IEC 60336-2005 Izixhobo zombane zonyango-iindibano zetyhubhu zeX-ray zokuxilongwa kwezonyango-Iimpawu zeendawo ezigxininisekileyo

Inkcazo

● Uluhlu luqulunqwe ngolu hlobo lulandelayo:

MWHX7010

Umbhobho

A

Isokethi yamandla ombane aphezulu ene-90 degree direction

MWTX70-1.0/2.0-125

B

Isokethi yamandla ombane aphezulu ene-270 degree direction

Idatha yoBugcisa

Ipropati

Inkcazo

Umgangatho

Amandla engeniso yesiqhelo ye anode

F 1

F 2

IEC 60613

21kW(50/60Hz)

42.5kW(50/60Hz)

 

Umthamo wokugcina ubushushu be-Anode

100 kJ ( 140kHU)

IEC 60613

Ubuninzi bomthamo wokupholisa we-anode

475W

 
Umthamo wokugcina ubushushu

900kJ

 
Max.ukutshatyalaliswa kobushushu okuqhubekayo ngaphandle kwe-Air-circular

180W

 
Izinto ze-AnodeI-Anode yokwambathisa izinto eziphezulu

I-Rhenium-Tungsten-TZM(RTM)

I-Rhenium-Tungsten-(RT)

 
I-engile ekujoliswe kuyo (Ref: i-reference axis)

16 °

IEC 60788

X-reyi indibano ityhubhu ukuhluzwa ngokwendalo

1.5 mm Al / 75kV

IEC 60601-1-3

Indawo ekujongwe kuyo ixabiso legama (ama)

F1(ingqwalasela encinci)

F2(ujoliso olukhulu)

IEC 60336

1.0

2.0

 
I-X-ray ityhubhu yombane ngegamaRadiographic

I-Fluoroscopic

125kV

100kV

IEC 60613

Idatha yokufudumeza kwe-cathode 

Max.yangoku

Ubuninzi bombane

≈ / AC, <20 kHz

 

F1

F 2

 

5.1A

≈5.87.8V

5.1 A

≈7.710.4 V

 
Ukuvuza kwemitha kwi-150 kV / 3mA kumgama we-1m

1.0mGy/h

IEC60601-1-3

Ubuninzi bemitha yemitha

573 × 573mm kwi-SID 1m

 
Ubunzima bendibano yetyhubhu ye-X-ray

Malunga.18kg

 

 

Iimeko zokusebenza, ukugcinwa kunye nokuthutha

Imida

Imida yoMsebenzi

Imida yezoThutho noGcino

Ubushushu obugciniwe

Ukusuka kwi-10ukuya ku40

Ukususela kwi-20to 70

Ubuntu bezizalwane

≤75%

≤93%

Uxinzelelo lweBarometric

Ukusuka kwi-70kPa ukuya kwi-106kPa

Ukusuka kwi-70kPa ukuya kwi-106kPa

 

Amaxabiso angundoqo eStator

I-stator yesigaba esi-1

Indawo yovavanyo

C-M

C-A

Ukuxhathisa komoya

≈18.0…22.0Ω

≈45.0…55.0Ω

Umthamo wombane ovumelekileyo wokusebenza (ukuqhuba)

230V±10%

Cebisa ukusebenza kwamandla ombane (ukusebenza)

160V±10%

I-voltage ye-Braking

70VDC

I-voltage esebenzayo ekutyhilekeni

80Vrms

I-voltage esebenzayo kwi-fluoroscopy

20V-40Vrms

Ixesha lokuqalisa (kuxhomekeke kwinkqubo yokuqalisa)

1.2s

Isilumkiso

Isilumkiso sokujongana neX-reyi Generator

1.Ukuqhekeka kweZindlu
Ungaze ufake igalelo kumandla abekiweyo kwindibano yetyhubhu yeX-reyi
Ukuba amandla okufakwayo adlula imilinganiselo ye-tube, inokubangela ukuba i-anode igqithise kakhulu, i-tube glass ityhutter, kwaye ekugqibeleni ingabangela iingxaki ezinzulu ngenxa yokugqithisa okubangelwa yi-vaporization yeoli ngaphakathi kwendibano yezindlu.Kwimeko enzima apho ukuphuka kwezindlu ngenxa yokugqithiswa, ukutshintshwa kwe-thermal yokhuseleko kungenakukwazi ukukhusela ityhubhu ye-X-ray, nokuba iyasebenza.
Iindawo zokutywina zezindlu ziyaqhekeka.
Ukulimala komntu kubandakanya ukutshisa ngenxa yokuphuma kweoli eshushu.
Ingozi yomlilo ngenxa yethagethi ye-anode evuthayo.
I-X-ray generator kufuneka ibe nomsebenzi wokukhusela olawula amandla okufakwayo ukuba abe ngaphakathi kwenkcazo yetyhubhu.

2.Ukothuka koMbane
Ukuthintela umngcipheko wokothuka kombane, esi sixhobo kufuneka siqhagamshelwe kuphela kubonelelo olunomhlaba okhuselayo.

 3.Akukho ukulungiswa kwesi sixhobo kuvunyelwe !!

Izilumkiso

Isilumkiso sokujongana neX-reyi Generator

1.Ngaphezu komlinganiselo
Amandla amaninzi kwi-shot eyodwa angabangela ukungaphumeleli kwendibano ye-X-ray ityhubhu.Kubalulekile ukuphonononga ngokucophelela i-data sheet yobugcisa kwaye ulandele imiyalelo echaziweyo ukuze ugweme umonakalo.

2.Uhluzo olusisigxina
Imimiselo yomthetho icacisa inani elipheleleyo lokuhluzwa okufunekayo kunye nomgama omncinci phakathi kwendawo yokugxila kwi-X-ray kunye nomzimba womntu.
They kufuneka kuthotyelwe ummiselo.

3.Ukhuseleko lokutshintsha kweThermal
X-reyi indibano yetyhubhu inokhuseleko lokutshintsha kwe-thermal ukunqanda amandla egalelo angaphezulu xa indlu yetyhubhu ifikelela kubushushu(80yokutshintsha-vula.
Ukutshintsha akukhuthazwa ukudibanisa i-coil ye-stator kwisekethe yochungechunge.
Nokuba utshintsho luyasebenza, ungaze ucime umbane wenkqubo.Iyunithi yokupholisa kufuneka ivulwe ukuba isetyenziswe kunye nesistim.

4.Ukungasebenzi kakuhle okungalindelekanga
Iindibano zetyhubhu ze-X-ray zinokungasebenzi kakuhle okanye zingaphumeleli ngokungalindelekanga, zenza umngcipheko weengxaki ezinzulu.Kubalulekile ukuba kubekho isicwangciso sokuqulela ukuthintela nokusombulula naziphi na iingxaki ezinokuvela kulo mngcipheko.

5.Usetyenziso Olutsha
Ukuba uceba ukusebenzisa le mveliso kwisicelo esitsha esingachazwanga kolu xwebhu, okanye ukuba uceba ukusebenzisa uhlobo olwahlukileyo lwe-X-ray generator, nceda uqhagamshelane nathi ukuze uqinisekise ukuhambelana nokufumaneka.

Isilumkiso kuMsebenzi

1 .Ukusasazeka kweX-reyiukhuselo

Le mveliso izalisekisa iimfuno ze-IEC 60601-1-3.

Le ndibano yetyhubhu ye-X-reyi ikhupha imitha ye-X-reyi ekusebenzeni.Kuphela ngokuhambelanayo kuphela ngabasebenzi abaqeqeshiweyo nabaqeqeshiweyo abavumelekileyo ukuba basebenzise indibano yetyhubhu ye-X-ray.

Iziphumo ezifanelekileyo ze-physiologic zinokubangela ingozi kwisigulana, ukuveliswa kwenkqubo kufuneka kuthathe ukhuseleko olufanelekileyo ukunqanda imitha ye-ionization.

2.Dielectric 0il

Indibano yetyhubhu yeX-reyi ine-dielectric 0il equlathe uzinzo lombane ophezulu.Njengoko iyityhefu kwimpilo yabantu,ukuba ibonakaliswe kwindawo engathintelwanga,kufuneka ilahlwe ngokulandelayo kummiselo wendawo.

3 .I-Operation Atmosphere

Indibano yetyhubhu yeX-reyi ayivumelekanga ukuba isetyenziswe kwi-atmosfera yegesi enokutsha okanye edlayo ·

4.Lungisa iTubhu yangoku

Ngokuxhomekeke kwiimeko zokusebenza,iimpawu zomcu zinokutshintshwa.

Olu tshintsho lunokuthi lube sesichengeni esingaphezulu kweqondo lokuvezwa kwimibhobho yeX-reyi.

Ukuthintela indibano yetyhubhu yeX-reyi ukuba yonakale,lungisa i-tube yangoku rhoqo.

Ngaphandle xa ityhubhu ye-X-reyi ine-arcing Ingxaki kwi-alukusetyenziswa ixesha elide,ukulungiswa kombhobho wangoku kuyafuneka.

5.X-ray Tube Housing Ubushushu

Sukuchukumisa umphezulu wezindlu zetyhubhu yeX-ray nje emva kokusebenza ngenxa yobushushu obuphezulu.

Hlala ityhubhu yeX-reyi ukuze upholiswe.

6.Imida yokusebenza

Ngaphambi kokusetyenziswa,Nceda uqinisekise imeko yokusingqongileyo ingaphakathi kwiiIimits zokusebenza.

7.Nakuphi na ukungasebenzi kakuhle

Nceda uqhagamshelane ne-SAILRAY ngokukhawuleza,ukuba kukho ukungasebenzi kakuhle kwendibano yetyhubhu ye-X-ray kubonwa.

8.Ukulahlwa

Indibano yetyhubhu yeX-reyi kunye netyhubhu iqulethe izinto ezifana neoyile kunye nesinyithi esinzima apho ukulahla okusingqongileyo kunye nokufanelekileyo ngokuhambelana nemithetho esemthethweni yesizwe kufuneka kuqinisekiswe. Ukulahlwa njengenkunkuma yasekhaya okanye yemizi-mveliso akuvumelekanga. Umenzi unazo. ulwazi olufunekayo lobuchwephesha kwaye iya kuthatha indibano yetyhubhu yeX-reyi emva ukulahlwa.

Nceda uqhagamshelane nenkonzo yabathengi ngale njongo.

Iigophe zokukhutshwa kwecathode

umfanekiso we-18
umfanekiso we-18

Ukuba (A) INdawo yokuJonga eNcinci

Ukuba(A) Indawo ekuJoliswe kuyo enkulu

Ukulayisha okukodwa kunye nochungechunge

Iimeko:ISigaba seSithathu seTube Voltage

I-Stator Power Frequency 50Hz/60Hz

Imifanekiso engama-20
Umfanekiso we22

Ukufudumeza kunye nokupholisa ijika le-anode

  IEC60613

Umfanekiso we23

Ukufudumeza kunye nokupholisa ijika lendibano yetyhubhu ye-X-reyi

Iimpawu zeThermal zezindlu

Umfanekiso we24

X-reyi indibano ityhubhu imizobo ebukhulu

SRMWHX7010A

Umfanekiso we25

SRMWHX7010B

Umfanekiso we26

INdibano yoHluzo kunye neCandelo lokuwela iZibuko

Umfanekiso we27

I-Rotor Connector Wiring

Umfanekiso we28

  • Ngaphambili:
  • Okulandelayo:

  • Ubuncinci boMyalelo woMyalelo: 1pc

    Xabiso:Negotiation

    Iinkcukacha zokupakisha: I-100pcs ngebhokisi okanye ilungiselelwe ngokobuninzi

    Ixesha lokuhanjiswa: Iiveki ze-1 ~ 2 ngokobuninzi

    Imigaqo yentlawulo: 100% T/T kwangaphambili okanye WESTERN UNION

    Ukubonelela ngeAmandla: 1000pcs / ngenyanga

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi